note senet instruction for installing packet forwarder is here if needed:https://docs.senetco.io/dev/gw/TektelicKona16/
Configuration On Senet Portal
Log into Senet Dev portal https://portal.senetco.io/
navigate to base station tap and select the + on the menu at the top
Enter Gateway EUI which is noted on the device label GWID and also found on the test certificate
Enter appropriate name for the gateway which allow us to identify it
Enter the serial number, this is the complet T number with the Release version omitted, “_” added followed by the serial number, this found on the test Certificate or on the device label example T0005130_2403J0038
Select device Model Number
Select the gateways Band (region EU/US ETC)
for US 8CH gateways Select sub band 2 which will allow the tags to roam on Helium
CH8-15,65 (65 is the gateways TX CH)
For 16CH gateways Select sub band 1&2 (CH0-15)
leave Override CH mask as blank
Leave LoraWAN Data processing as Enabled
Admin Status: in service
alert level: disabled (to not get notification of gateway issues)
select Allow LVN traffic
leave filter join traffic unticked
press Save
once the gateway is powers the indicator on the portal will turn green, Note by overing over the indicator further detail on the gateway status is displayed
NOTE: For CLASS B or CLASS C (Used for FUOTA) operation the gateway must have GNSS reception, the gateway must have view of the SKY, if senet detect poor GNSS signal or frequent loss of GNSS signal they will disable class B and Class C operation as GNSS is required for time synchronization.