...
enter command
Code Block system_version
”to check BSP version and ensure the device is running 5.1 or higher Macro or 2.1 for Enterprise
...
remove root access using command
Code Block sudo opkg remove disable-root-login
and entering the password again
enter command
Code Block sudo SUsu Root
check you are in the root location by using command whoami
remove tektelic packet forwarder and MQQT bridge
...
power cycle the gateway or use command
Code Block tektelic_reset
Log back into the gateway via SSH using username Root and serial number as the password, note the password is case sensitive. the serial number is founf found on the label on the gateway or on the test certificate, note the certifcate certificate shows the TcodeT code, release followed by the serial number EG “T0005130 G1 2403J0038” the serial number is the last 9 chars,
Instal Install Senet Packet forwarder for developer not the RAN provider as this will disable future access via SSH.
Kona Macro:
Code Block dlF=lgwInstaller_02_22_10.sh;dlC=senetco;wget --no-check-certificate http://docs.${dlC}.io/downloads/02_22_10/$dlF -O $dlF && chmod +x $dlF && ./${dlF} -c ${dlC} -t DEV
Kona Enterprise:
Code Block |
---|
dlF=lgwInstaller_02_22_10.sh;dlC=senetco;wget --no-check-certificate http://docs.${dlC}.io/downloads/02_22_10/$dlF -O $dlF && chmod +x $dlF && ./${dlF} -c ${dlC} -t DEV |
note Macro : senet instruction for installing packet forwarder is here if needed:https://docs.senetco.io/dev/gw/TektelicKona16/
note Enterprise : senet instruction for installing packet forwarder is here if needed:https://docs.senetco.io/dev/gw/TektelicKonaMicroEnterprise/
Configuration On Senet Portal
Log into Senet Dev portal https://portal.senetco.io/
navigate to base station tap and select the + on the menu at the top
Enter Gateway EUI which is noted on the device label GWID and also found on the test certificate
Enter appropriate name for the gateway which allow us to identify it
Enter the serial number, this is the complet T number with the Release version omitted, “_” added followed by the serial number, this found on the test Certificate or on the device label example T0005130_2403J0038
Select device Model Number
Select the gateways Band (region EU/US ETC)
for US 8CH gateways Select sub band 2 which will allow the tags to roam on Helium
Enterprise:CH8-15,65 (65 is the gateways TX CH)
Macro: For 16CH gateways Select sub band 1 & 2 (CH0-15)
leave Override CH mask as blank
Leave LoraWAN Data processing as Enabled
Admin Status: in service
alert level: disabled (to not get notification of gateway issues)
select Allow LVN traffic
leave filter join traffic unticked
press Save
once the gateway is powers the indicator on the portal will turn green, Note by overing over the indicator further detail on the gateway status is displayed
NOTE: For CLASS B or CLASS C (Used for FUOTA) operation the gateway must have GNSS reception, the gateway must have view of the SKY, if senet detect poor GNSS signal or frequent loss of GNSS signal they will disable class B and Class C operation as GNSS is required for time synchronization.